Insulated Flex Duct In Attic
Skip to main content.
Insulated flex duct in attic. The master flow 6 in. Or excess flex duct. Insulated flexible duct r6 silver jacket is used in standard heating and air conditioning hvac systems and some venting applications. In existing homes with vented attics and hvac ducts that are installed on the attic floor bury ducts in blown attic insulation when adding or increasing attic insulation.
Ducts are to be part of what is inside the house not part of. Most attic ducts are insulated flex ducts that is flex ducts with r 6 or r 8 fiberglass insulation along with an exterior polyethylene jacket. For pricing and availability. Insulated flexible duct r6 silver jacket is used in standard heating and air conditioning hvac systems and some venting applications.
People can not carry ladders up into a attic and them place them onto 1 1 2 wide boards so they can climb over ducts. Imperial 8 in x 300 in insulated polyester flexible duct. The duct has r6 insulation which contains 33 more insulation than the standard r4 2 product. Looking at the cooling side only the additional load would be.
The higher the r value the pricier the ducting. Just blow the attic to r 38 and over the top of ducts if needed. The lower the cooler it is. Find a store near me.
The duct has r6 insulation which contains 33 more insulation than the standard r4 2 product. R 8 duct insulation 5 227 btu hour. The master flow 4 in. The attic is a hot dirty nasty place.
This additional insulation provides greater thermal efficiency to save energy. Before adding blown insulation inspect and test the ducts for missing or torn duct insulation. Ducts up high get tore up. This additional insulation provides greater thermal efficiency to save energy.
Find flexible duct at lowe s today. Not part of what is in the attic. Lambro 4 in x 96 in foil. According to rightsuite the software we use the supply ducts have about 560 square feet of surface area and the return ducts 101 square feet.
The doe s building america program recommends beds buried encapsulated ducts. Heaping insulation over the ducts is fine in dry climates but can cause condensation on the duct insulation jacket in humid climates. Blown in insulation is cheap. When these ducts are exposed to exterior air the plastic jacket never gets cold enough to permit condensation because the hot attic air keeps the plastic jacket warm.
R value of insulated ducts flexible ductwork running in open space like an attic will be insulated from about r6 to r10. Disconnected or leaking ducts. The flex ducts were literally filled shut with ice in the low spots compressing the scant insulation layer beneath them. By spraying closed cell foam on the ducts before burying them in attic insulation you prevent the condensation problem.
However this is a cost that pays for itself quickly so choose higher r values when given an option. All the ducts are in the attic.