Irc 2012 Attic Ventilation Requirements
The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
Irc 2012 attic ventilation requirements. And this guideline you ll need a minimum of. Space irc 2012 limits the net free ventilation reduction from 1 150 to 1 300 for buildings in climate zones 6 7 and 8. Near ridge of the roof. Vented attics shall have a minimum net free ventilation area at least 1 300 of the area of the vented space.
Unvented attic assemblies code notes 2009 irc 2012 irc adequate attic ventilation is a long standing requirement in building codes for moisture control. Nrca guidelines regarding attic ventilation nrca recommends designers provide at least 1 square foot of nfva for every 150 square feet of attic space 1 150 ventilation ratio measured at the attic floor level ceiling. For large volume attics such as where roof slopes are greater than 8 12 designers also should consider increasing the amount of attic ventilation. Always have a balanced ventilation system.
Enclosed attics and enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters shall have cross ventilation for each separate space by ventilating openings protected against the entrance of rain or snow. Based on your 1100 sq. Between half and two thirds of the provided ventilation shall be installed at the eaves. Overflow drains having the same size as the roof drains shall be installed with the inlet flow line located 2 inches 51 mm above the low point of the roof or overflow scuppers having three times the size of the roof drains and having a minimum opening height of 4 inches 102 mm shall be installed in the adjacent parapet walls with the inlet flow located 2 inches 51 mm above the low point of the roof served.
Ventilation openings shall have a least dimension of 1 16 inch 1 6 mm minimum and 1 4 inch 6 4 mm maximum. However unvented attics can reduce residential energy needs and are allowed by the code under certain conditions. One ventilation opening shall be within 3 feet 915 mm of each corner of the building. Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space.
The minimum net area of ventilation openings shall not be less than 1 square foot 0 0929 m2 for each 150 square feet 14 m2 of under floor area.