Irc 2012 Roof Pitch
All other data can be found in the.
Irc 2012 roof pitch. Where the roof sheathing is less than 3 4 inch 19 mm thick the. Rafter span table and 2012 irc requirements. Minimum roof slope roof pitch r905 3 2. R802 10 1 truss design drawings.
Where the roof sheathing is less than 3 4 inch 19 1 mm thick the nails. This means for every 12 horizontal units the roof must rise a minimum of two and one half vertical units. The existing roof or roof covering is water soaked or has deteriorated to the point that the existing roof or roof covering is not adequate as a base for additional roofing. Roof geometry wood truss requirements 2012 irc section r802 10 addresses the requirements for wood metal plate connected wood trusses.
Fasteners for asphalt shingles shall be galvanized steel stainless steel aluminum or copper roofing nails minimum 12 gage 0 105 inch 3 mm shank with a minimum 3 8 inch diameter 10 mm head astm f 1667 of a length to penetrate through the roofing materials and a minimum of 3 4 inch 19 mm into the roof sheathing. The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures. The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures. Truss design drawings prepared in conformance to section r802 10 1 shall be provided to.
Clay and concrete roof tiles can only be installed on roof slopes of 2 1 2 12 or greater. 3 the existing roof has two or more applications of any type of roof covering. Fasteners for asphalt shingles shall be galvanized stainless steel aluminum or copper roofing nails minimum 12 gage 0 105 inch 2 67 mm shank with a minimum 3 8 inch diameter 9 5 mm head of a length to penetrate through the roofing materials and a minimum of 3 4 inch 19 1 mm into the roof sheathing. It brings together all building plumbing mechanical fuel gas energy and electrical provisions for one and two family residences.
Posted on by. These rafter spans are for 2 lumber a ground snow load of 30 psf the ceiling not attached to rafters and a dead load of 10 psf. Roof pitch 13 12 to 12 12 or greater table r301 6 r802 3 table 3. May 2012 amendments legislative format floors 2012 international residential code 121 table r502 5 1 girder spansa b aand header spans b for exterior bearing walls maximum spans for douglas fir larch hem fir southern pine and spruce pine firb and required number of jack studs girders and.
January 2012 code for residential buildings that creates minimum regulations for one and two family dwellings of three stories or less.